Translation

English
English Chinese (Simplified)
This settings should remain ON unless your Cacti instances is running on either ZFS or FusionI/O which both have internal journaling to accomodate abrupt system crashes. However, if you have very good power, and your systems rarely go down and you have backups, turning this setting to OFF can net you almost a 50% increase in database performance. 除非您的Cacti实例在ZFS或FusionI / O上运行,并且两者都具有内部日记功能以适应突然的系统崩溃,否则此设置应保持为ON。但是,如果您的电源非常好,并且系统很少宕机并且有备份,那么将此设置设置为OFF可以使数据库性能提高近50%。
This is where metadata is stored. If you had a lot of tables, it would be useful to increase this. 这是元数据存储的地方. 如果您有很多表,那么增加这个值会很有用.
Rogue queries should not for the database to go offline to others. Kill these queries before they kill your system. 恶意查询不应该让数据库脱机给其他人. 请在杀死您的系统之前杀死这些查询.
Maximum I/O performance happens when you use the O_DIRECT method to flush pages. 使用O_DIRECT方法刷新页面时,会发生最大I / O性能。
Setting this value to 2 means that you will flush all transactions every second rather than at commit. This allows %s to perform writing less often. 将此值设置为2 意味着您将每秒刷新所有事务,而不是在提交时刷新. 这使得 %s 可以减少写入次数.
With modern SSD type storage, having multiple io threads is advantageous for applications with high io characteristics. 采用现代SSD 类型的存储器,具有多个IO 线程对于具有高IO 特性的应用是有利的.
As of %s %s, the you can control how often %s flushes transactions to disk. The default is 1 second, but in high I/O systems setting to a value greater than 1 can allow disk I/O to be more sequential 从 %s %s开始,您可以控制 %s将交易刷新到磁盘的频率. 默认值是1秒,但是在高I/O系统中设置为大于1的值可以允许磁盘I/O更有序
With modern SSD type storage, having multiple read io threads is advantageous for applications with high io characteristics. Depending on your MariaDB/MySQL versions, this value can go as high as 64. But try to keep the number less than your total SMT threads on the database server. 采用现代SSD类型的存储器,具有多个读取IO线程对于具有高IO特性的应用是有利的.
With modern SSD type storage, having multiple write io threads is advantageous for applications with high io characteristics. Depending on your MariaDB/MySQL versions, this value can go as high as 64. But try to keep the number less than your total SMT threads on the database server. 采用现代SSD类型的存储器,具有多个写入IO线程对于具有高IO特性的应用是有利的.
%s will divide the innodb_buffer_pool into memory regions to improve performance for versions of MariaDB less than 10.5. The max value is 64, but should not exceed more than the number of CPU cores/threads. When your innodb_buffer_pool is less than 1GB, you should use the pool size divided by 128MB. Continue to use this equation up to the max the number of CPU cores or 64. %s会将innodb_buffer_pool分成内存区域以提高性能. 最大值是64.当您的innodb_buffer_pool小于1GB时,您应该使用池大小除以128MB. 继续使用这个等式,最大值为64.
%s will divide the innodb_buffer_pool into memory regions to improve performance for versions of MySQL upto and including MySQL 8.0. The max value is 64, but should not exceed more than the number of CPU cores/threads. When your innodb_buffer_pool is less than 1GB, you should use the pool size divided by 128MB. Continue to use this equation up to the max of the number of CPU cores or 64. %s会将innodb_buffer_pool分成内存区域以提高性能. 最大值是64.当您的innodb_buffer_pool小于1GB时,您应该使用池大小除以128MB. 继续使用这个等式,最大值为64.
If you have SSD disks, use this suggestion. If you have physical hard drives, use 200 * the number of active drives in the array. If using NVMe or PCIe Flash, much larger numbers as high as 100000 can be used. 如果您有SSD磁盘,请使用此建议。如果您有物理硬盘驱动器,请使用200 *阵列中的活动驱动器数量。如果使用NVMe或PCIe闪存,可以使用高达100000的更大数字。
If you have SSD disks, use this suggestion. If you have physical hard drives, use 2000 * the number of active drives in the array. If using NVMe or PCIe Flash, much larger numbers as high as 200000 can be used. 如果您有SSD磁盘,请使用此建议。如果您有物理硬盘驱动器,请使用2000 *阵列中的活动驱动器数量。如果使用NVMe或PCIe Flash,则可以使用高达200000的更大数字。
If you have SSD disks, use this suggestion. Otherwise, do not set this setting. 如果您有SSD磁盘,请使用此建议。否则,请勿设置此设置。
With modern SSD type storage, having multiple read io threads is advantageous for applications with high io characteristics. 采用现代SSD类型的存储器,具有多个读取IO线程对于具有高IO特性的应用是有利的.
With modern SSD type storage, having multiple write io threads is advantageous for applications with high io characteristics. 采用现代SSD类型的存储器,具有多个写入IO线程对于具有高IO特性的应用是有利的.
When using MariaDB 10.2.4 and above, this setting should be off if atomic writes are enabled. Therefore, please enable atomic writes instead of the double write buffer as it will increase performance. 使用 MariaDB 10.2.4 及更高版本时,如果启用了原子写入,则应关闭此设置。因此,请启用原子写入而不是双写入缓冲区,因为它会提高性能。
When using MariaDB 10.2.4 and above, you can use atomic writes over the doublewrite buffer to increase performance. 使用 MariaDB 10.2.4 及更高版本时,您可以在双写缓冲区上使用原子写入来提高性能。
%s Tuning %s 调优
Note: Many changes below require a database restart 注意: 下面的许多修改要求重启数据库才能生效
Variable 变量
Current Value 当前值
Recommended Value 推荐值
Comments 注释
PHP %s is the minimum version PHP %s 是最低版本要求
A minimum of %s memory limit 至少 %s MB 内存
A minimum of %s m execution time 至少 %s m 执行时间
A valid timezone that matches MySQL and the system 与MySQL和系统匹配的有效时区
A useful name for this VDEF. VDEF 的名称.
Click 'Continue' to Delete the following External Link. 点击 '继续' 删除下列用户域.
Click 'Continue' to Delete following External Links. 点击 '继续' 删除下列用户域.
Component Translation Difference to current string
This translation Propagated Translated Cacti/core
The following string has the same context and source.
Propagated Translated Cacti/core (v1.2.x)

Loading…

No matching activity found.

Browse all component changes

Glossary

English Chinese (Simplified)
No related strings found in the glossary.

String information

Source string location
lib/utility.php:1198
String age
3 years ago
Source string age
3 years ago
Translation file
locales/po/zh-CN.po, string 4109